MIL-DTL-22992G
4. VERIFICATION
4.1 Classification of inspections. The inspection requirements specified herein are classified as
follows:
Qualification inspection (see 4.4).
a.
Conformance inspection (see 4.5).
b.
4.2 Test equipment and inspection facilities. Test and measuring equipment and inspection facilities
of sufficient accuracy, quality and quantity to permit performance of the required inspection shall be
established and maintained by the supplier. The establishment and maintenance of a calibration
system to control the accuracy of the measuring and test equipment shall be in accordance with
ISO 17025 and NCSL Z540.3.
4.2.1 Established reliability assurance program. A reliability assurance program shall be established
and maintained in accordance with MIL-STD-790. Evidence of such compliance shall be verified by the
qualifying activity of this specification as a prerequisite for qualification and continued qualification.
4.2.1.1 Statistical process control (SPC). A SPC program shall be established and maintained in
accordance with EIA-557. Evidence of such compliance shall be verified by the qualifying activity as a
prerequisite for qualification and retention of qualification.
4.2.2 Fungus resistance certification. Certification of method 508.6 of MIL-STD-810 is required
(see 3.3.9).
4.3 Inspection conditions. Unless otherwise specified herein, all inspections shall be performed in
accordance with the test conditions specified in the "GENERAL REQUIREMENTS" of EIA-364.
4.4 Qualification inspection (see table VIII). Qualification inspection shall be performed at a
laboratory acceptable to the qualifying activity (see 6.4) on sample units produced with equipment and
procedures normally used in production.
4.4.1 Qualification samples. Qualification inspection samples shall consist of the following:
a. Two complete mating assemblies of straight plug and wall mounting receptacle, in each
size of either class C or class R, having each type finish for which qualification is sought,
and containing the greatest complement of contacts for that size. If class R assemblies
are provided and additional qualification is desired for class C and (or) class J
connectors, then one additional mating assembly of straight plug and wall mounting
receptacle in each size of either class C or class J containing the greatest complement of
contacts for that size shall be provided. Suitable adapters less protective covers shall
also be provided.
19
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business