MIL-DTL-22992G
TABLE VIII. Qualification inspection. 1/
Inspection
Requirement
Test
Connector
Cable
paragraph
paragraph assemblies
adapters
Group 1
Visual and mechanical examination
3.1, 3.3.1 to
X
X
Magnetic permeability
X
Shell-to-contact resistance grounding
X
Shell-to-shell conductivity (conductive
X
finishes only)
Contact retention (class L)
X
Contact resistance
X
Dielectric withstanding voltage
X
Thermal shock (temperature cycling)
X
Air leakage
X
Contact retention (classes C, J, R)
X
Insert retention
X
Insulation resistance
X
Humidity
X
X
Insulation resistance
X
X
Dielectric withstanding voltage
X
X
Durability
X
Salt spray (corrosion)
X
X
Shell-to-shell conductivity (conductive
X
finishes only)
Contact resistance
X
X
Cable pull-out
X
X
See footnotes at end of table.