4.4.1.1 Qualification of additional connectors or accessories. For connectors or accessories which
differ only in detail from those submitted for qualification, the manufacturer's test report need only provide
inspection and test data necessary to validate the differences, with information on identical features for
which no inspection or test was performed. Qualification for nongrounding assemblies may be granted by
similarity if both abrasion type panels are used in qualification for grounding assemblies. Connectors of a
less dense configuration than those listed on the qualified products list may be qualified by similarity
provided samples are furnished to the qualifying activity.
4.4.1.2 Qualification of adapters, protective covers and stowage receptacles and cable grips.
Manufacturers of adapters, protective covers, stowage receptacles and cable grips, or manufacturers who
are not producing mating connectors to this specification, shall submit data substantiating that
qualification inspection of those items was performed with an appropriate number of approved electrical
connectors as specified in 4.4.1 and in accordance with the applicable requirements of this specification
and in the order shown in table VIII.
4.4.2 Inspection routine. Qualification inspection of connectors, adapters, protective covers, cable
grips and stowage receptacles shall consist of all the tests of this specification described under test
Mated connectors shall be subjected to the applicable tests listed in table VIII.
a.
Connectors for group 1 need not be wired unless otherwise specified by the individual
test method paragraph. Connectors for group 2 shall be wired and sealed. Samples
required are as follows:
(1) Class C and R
Group 1 - One pair (either class).
Group 2 - One pair (same class as selected for group 1).
(2) Class L
Group 1 - One pair of MS90555 or MS90556, or as applicable (see 4.4.1b).
Group 2 - One pair of each of the following, or as applicable (see 4.4.1b).
MS90555 and MS90556.
a.
b.
MS90557 and MS90558.
applicable, shall be subjected to the thermal shock test of 4.6.6 and the air leakage test
of 4.6.7.
Fifty-five sockets and five pin contacts of each size selected as described in 4.4.1d shall
c.
be subjected to the applicable tests listed in group 4 of table VIII, as follows:
(1) Fifty sockets shall be subjected to the test of 4.6.23. Following this test, the size 16
One or two panels, as applicable, selected as described in 4.4.1e shall be subjected to
d.
the applicable tests listed in group 5 of table VIII.
Protective covers, cable grips and stowage receptacles selected as described in 4.4.1f,
e.
24