TABLE I. First article, conformance, and single item inspection.
First article
Conformance
Single item
Test
Inspection
Requirement
Type
Type
Type
method
I
II III IV V VI VII I
II III IV V VI VII I II III IV V VI VII
GROUP A
General examination
X X
X
X X X
X
X
X
X
X
X
X
X X X
X
X
X
X
X
and 3.7
Operation
XX
X
XX
-
-
X
X
X
X
X
-
-
-
-
-
-
-
-
-
GROUP B
Insulation resistance
X X
X
X X
-
-
X
X
X
X
X
-
-
X X
X
X
X
-
-
Continuity check
XX
X
XX
-
-
X
X
X
X
X
-
-
XX
X
X
X
-
-
O-ring
XX
X
XXX
-
X
X
X
X
X
X
-
XX
X
X
X
X
-
Hardness
Brinell or Rockwell
-
X
X
X
-
X
-
-
X
X
X
-
X
-
-
X
X
X
-
X
-
Durometer
-
-
X
X
-
-
-
-
-
X
X
-
-
-
-
-
X
X
-
-
-
Dye penetrant
-
X
X
XXX
X
-
X
X
X
X
X
-
-
X
X
X
X
X
-
Bonding
X
-
-
-
-
-
-
X
-
-
-
-
-
-
-
-
-
-
-
-
-
(non-destructive)
Vibration
XX
X
XX
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Shock
XX
X
XX
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Underwater explosion shock 4/
-
-
X
X
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Hydrostatic pressure (24 hours) 1/ 3/
XX
X
XX
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Hydrostatic pressure (2 hours) 2/ 3/
- X 3/ X
-
-
-
-
-
-
X
X
X
-
-
-
X
X
X
X
-
-
Dielectric withstanding voltage
XX
X
XX
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
GROUP C
Bonding (destructive)
X
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-