MIL-DTL-55235A
4.4
Inspection covered by subsidiary documents. The following shall be inspected under the
applicable subsidiary documents as part of the inspection required by this specification and the inspection
requirement specified in the contract.
Item
Where required
Brass
3.3.1
Copper Beryllium
3.3.2
FEP
3.3.3
Silicone Rubber
3.3.4
Solder
3.3.5
Dissimilar Metals
3.3.6
Silver Plating
3.4.1
Gold Plating
3.4.2
Screw Threads
3.4.3
Marking
3.12
4.5 Conformance Inspection of the connectors before preparation for delivery. The contractor shall
perform the inspection specified in 4.4 and 4.5.1 through 4.5.4. This does not relive the contractor of his
responsibility for performing any additional inspection which is necessary to control the quality of the
product and to assure compliances with all specification requirements. The Government will review and
evaluate the contractor's inspection procedures and examine the contractor's inspection records. In
addition, the Government, at its discretion, may perform all or any part of the specified inspection, to
verify the contractor's compliance with specified requirements (see 6.5). Test equipment for Government
verification inspection shall be made available by the contractor.
4.5.1. Sampling plan (Group A). Table II tests shall be performed on a production lot basis.
Samples shall be selected in accordance with Table IIa. If one or more defects are found, the lot shall be
screened for that particular defect and defects removed. A new sample of parts shall be selected in
accordance with Table IIa and all Group A tests again performed. If one or more defects are found in the
second sample, the lot shall be rejected and shall not be supplied to this specification.
4.5.1.1 Visual inspection (Group A inspection). Each connector shall be visually examined for
completeness, workmanship, and identification requirements. Attention shall be given to those
assemblies that require a gasket to determine the condition of the gasket. Gaskets missing, twisted,
buckled, kinked, or damaged in any way shall be cause for rejection. Group A inspection shall be
performed in any order acceptable to the Government.
8