MIL-DTL-55235A
TABLE II. Group A inspection.
Requirement
Inspection
Inspection
paragraph
paragraph
4.7.1
3.3
Visual and mechanical
3.4, 3.4.1, 3.4.2, 3.4.4,
Design and construction
4.7.1
and 3.4.4
4.7.1
3.8
Cable clamping
4.7.1
3.9
Assembly instructions
4.7.1
3.11
Outline mounting dimensions
4.7.1
3.12
Marking
4.7.1
3.23
Workmanship
4.7.2
3.10
Interchangeability dimensions
Electrical
4.7.3
3.13
Dielectric withstanding voltage
4.7.4
3.14
Insulation resistance
4.7.5
3.15
Contact resistance
1/ All electrical defects are considered major.
Table IIa. Inspection level.
Visual and mechanical inspection
Lot size
Major
Minor 1/
5
all
1
to
8
5
all
9
to
15
5
20
16
to
25
5
20
26
to
50
7
20
51
to
90
11
20
91
to
150
13
20
151
to
280
16
47
281
to
500
19
47
501
to
1,200
23
53
1,201
to
3,200
29
68
3,201
to
10,000
35
77
10,001
to
35,000
40
96
35,001
to
150,000
40
119
150,001
to
500,000
40
143
500,001
to
over
1/ Samples may be pulled from either the production lot itself or from samples
pulled from the lot for major defect testing.