MIL-PRF-39012/18H
REQUIREMENTS:
Dimensions and configuration: See figure 1.
Force to engage and disengage:
Longitudinal force - 3 pounds (13.34 N), maximum.
Torque 2.5 inch-pounds (.28 Nm), maximum.
Coupling proof torque: Not applicable.
Inspection conditions: Coupling torque not applicable.
Mating characteristics:
In accordance with MIL-STD-348 and figures 2 and 3 for dimensions.
Center contact (socket):
Oversize test pin: .057 inch (1.45 mm) diameter minimum (nonclosed entry contacts only).
Insertion depth: .125 inch (3.17 mm), minimum.
Number of insertions: 1.
Insertion force test: Steel test pin diameter .054 inch (1.37 mm), minimum.
Test pin finish: 16 microinches (0.406 µm).
Insertion force: 2 pounds (8.90 N), maximum.
Withdrawal force test: Steel test pin diameter .052 inch (1.32 mm) maximum.
Withdrawal force: 2 ounces (.56 N), minimum.
Test pin finish: 16 microinches (0.406 µm).
Hermetic seal: Not applicable.
Leakage (pressurized connectors): Not applicable.
Insulation resistance: Method 302 of MIL-STD-202, test condition B, 5,000 megohms minimum.
Center contact retention: 6 pounds (26.69 N), minimum axial force. Applicable to
captivated-center-contact connectors only.
Corrosion (salt spray): Method 101 of MIL-STD-202, test condition B.