MIL-DTL-83413C
b.
The results of tests performed for periodic inspection, group B, including the number and
mode of failures. The test report shall include results of all periodic inspection tests
performed and completed during the 36-month period. If the test results indicate
nonconformance to specification requirements, and corrective action acceptable to the
qualifying activity has not been taken, action may be taken to remove the failing product
from the qualified products list.
Failure to submit the report within 30 days after the end of each 24-month period may result in loss of
qualification for the product. In addition to the periodic submission of inspection data, the contractor shall
immediately notify the qualifying activity at any time during the 24-month period that the inspection data
indicates failure of the qualified product to meet the requirements of this specification.
In the event that no production occurred during the reporting period, a report shall be submitted certifying
that the company still has the capability and facilities necessary to produce the item. If during 2
consecutive reporting periods, there has been no production, the manufacturer may be required, at the
discretion of the qualifying activity, to submit a representative product of each style, to testing in
accordance with the qualification inspection requirements.
TABLE II. Qualification inspection, connectors and jumper assemblies. 1/
Clamp
Jumper
Requirement
Test
Inspection
Plug
Receptacle
connector assembly
paragraph
Paragraph
Group I
Visual and mechanical
4.7.1
3.1, 3.3, 3.4
X
X
X
X
Inspection
3.6, 3.8
4.7.2
3.5.1
X
X
Detent action
4.7.3
3.5.2
X
Handgrip force
4.7.4
3.5.3
X
Side loading
4.7.5
3.5.4
X
Torque
4.7.6
3.5.5
X
X
Engagement
4.7.7.1
3.5.6.1
X
X
Contact resistance
4.7.7.2
3.5.6.2
X
Clamp connector resistance
4.7.7.3
3.5.6.3
X
Assembly resistance
Group II
X
3.5.7
4.7.8
Cable attachment
X
3.5.8.1
4.7.9
Clamp release force (initial)
Clamp release force
X
3.5.8.2
4.7.9
(after conditioning)
X
3.5.9
4.7.10
Clamping life
X
3.5.10
4.7.11
Vibration
X
X
3.5.11
4.7.12
Durability
X
3.5.13
4.7.14
Flexibility
X
X
3.5.12
4.7.13
Tensile strength
Crush
X
3.5.14
4..7.15
See notes at end of table.