MIL-DTL-83413C
3.5.10 Vibration. When tested as specified in 4.7.11, there shall be no physical or mechanical damage
to the connector, other than normal surface wear. The connector shall meet the contact resistance
requirements of 3.5.6.1 and the detent action requirements of 3.5.1.
3.5.11 Durability. When tested as specified in 4.7.12, there shall be no evidence of mechanical damage
other than normal surface wear. The connector shall then meet the detent action requirements of 3.5.1,
and the contact resistance requirements of 3.5.6.1.
3.5.12 Tensile strength. When tested as specified in 4.7.13, the jumper cable assembly shall withstand
an axial force specified in the applicable specification sheets (see 3.1). It shall then meet the assembly
resistance requirements of 3.5.6.3.
3.5.13 Flexibility. When tested as specified in 4.7.14, the jumper cable assembly shall meet the tensile
strength requirement of 3.5.12 without breaking or stranding, and shall meet the assembly resistance
requirements of 3.5.6.3.
3.5.14 Crush. When tested as specified in 4.7.15, there shall be no evidence of mechanical damage,
the plugs shall meet the detent action requirements of 3.5.1, and the contact resistance requirements of
3.5.15 Humidity. When tested as specified in 4.7.16, there shall be no evidence of corrosion, and the
following requirements shall be met, as applicable:
a.
Clamp release force (see 3.5.8.1).
Contact resistance (see 3.5.6.1).
b.
c.
Clamp connector resistance (see 3.5.6.2).
d.
Assembly resistance (see 3.5.6.3).
e.
Detent action (see 3.5.1).
3.5.16 Temperature cycling. When tested as specified in 4.7.17, there shall be no evidence of physical
damage, and the following requirements shall be met, as applicable:
a.
Clamp release force (see 3.5.8).
b.
Contact resistance (see 3.5.6.1).
Clamp connector resistance (see 3.5.6.2).
c.
d.
Assembly resistance (see 3.5.6.3).
e.
Detent action (see 3.5.1).
3.5.17 Drop. When tested as specified in 4.7.18, the clamp connector shall function properly, and the
following requirements shall be met:
a. Clamp release force (see 3.5.8.1).
b. Clamp connector resistance (see 3.5.6.2).
3.5.18 Altitude-low temperature. When tested as specified in 4.7.19, there shall be no evidence of
physical damage, and the receptacles shall meet the detent action requirements of 3.5.1, the contact
resistance requirements of 3.5.6.1, and the assembly resistance requirements of 3.5.6.3, as applicable.