MIL-DTL-21097G
Inches
mm
Inches
mm
Inches
mm
Inches
mm
Inches
mm
Inches
mm
.0001
0.00
.125
3.18
.850
21.59
1.600
40.64
2.660
67.56
3.850
97.79
.003
0.08
.1350
3.43
.942
23.93
1.694
43.03
2.850
72.39
4.035
102.49
.005
0.13
.140
3.56
1.042
26.47
1.885
47.88
2.885
73.28
4.085
103.76
.010
0.25
.156
3.96
1.070
27.18
1.975
50.17
2.942
74.73
4.385
111.38
.0135
0.34
.342
8.69
1.085
27.56
2.011
51.08
3.085
78.36
4.502
114.35
.050
1.27
.375
9.53
1.142
29.01
2.085
52.96
3.225
81.92
4.600
116.84
.067
1.70
.542
13.77
1.285
32.64
2.285
58.04
3.255
82.68
4.812
122.22
.0700
1.78
.642
16.31
1.292
32.82
2.350
59.69
3.565
90.55
5.100
129.54
.100
2.54
.685
17.40
1.350
34.29
2.475
62.87
3.600
91.44
5.475
139.07
.1030
2.62
.792
20.12
1.585
40.26
2.585
65.66
3.685
93.60
5.750
146.05
6.374
161.90
NOTES:
1. Dimensions are in inches
2. Metric equivalents are given for information only.
FIGURE 4. Edge connector mechanical gages - Continued.
4.6.7 Temperature cycling (see 3.11). Mated connector assembly, receptacle, and the nominal thickness standard
printed wiring test board (see figure 2) shall be tested in accordance with test procedure EIA-364-32. The following
details shall apply:
a. Test condition I, 5 cycles. Temperature shall be -65° +0°, -5°C and 125° +3°, -0°C.
b. Measurements during cycling: During the fifth cycle, at temperature specified, the mated connector
assembly shall be mated and unmated without use of special tools.
4.6.8 Vibration (see 3.12). Connectors shall be tested in accordance with test procedure EIA-364-28. The following
details shall apply:
a. Mounting of specimens: Receptacle and printed wiring board or receptacle and standard printed wiring test
board shall be held together by normal means. For example, use of clamping arrangement utilizing the
mounting holes and framework to hold the printed wiring board of the standard printed wiring test board rigidly
in its respective receptacle is permitted. Wires shall be supported o a stationary frame not closer than 12
inches form the connectors.
b. Electrical-load conditions: All the contacts shall be connected in series to a suitable testing circuit with
at least 0.1 ampere flowing through the contacts.
c. Test condition: III.
d. Measurements during and after test: Contacts shall be monitored for continuity during and after the
test. Loss of continuity constitutes a failure.
4.6.9 Shock (see 3.13). The completely mated connector assembly, receptacle and printed wiring test board (see
figure 2), the composite connector and the printed wiring test board (see figure 2) with the individual contacts
assembled, of the composite connector with mating printed wiring board shall be tested in accordance with test
procedure EIA-364-27. The following details and exceptions shall apply:
a. Mounting method: All contacts shall be wired with the appropriate size wire. Wires shall be supported on a
stationary frame not closer than 12 inches from the connectors. Receptacle and printed wiring board, or
receptacle and standard printed wiring test board shall be held together by normal means. For example, use
of clamping arrangement utilizing holes and framework to hold the printed wiring board or the standard
printed wiring board rigidly in its respective receptacle is permitted.
23