MIL-DTL-83502E
4.8.7 Dielectric withstanding voltage (see 3.10). Sockets shall be tested in accordance with test
procedure EIA-364-20. The following details and exceptions shall apply:
a. Preparation - Mated with suitable test plug (see figure 2) but not mounted on a printed circuit
board.
b. Magnitude of test voltage - 600 volts, unless otherwise specified (see 3.1).
c.
Nature of potential - AC (rms).
d. Barometric pressure - Sea level.
e. Points of application of test voltage - The test voltage shall be applied between all odd-numbered
contacts connected together and all even-numbered contacts and all other metallic parts
connected together, unless otherwise specified (see 3.1).
f.
Method of connection of test voltage to specimen - Affix test probes to terminations described in
4.8.7e, by clips or solder.
4.8.8 Contact resistance (see 3.11). The contact resistance shall be measured as specified on figure 4.
A minimum of three contacts shall be measured on each test specimen in accordance with test procedure
EIA-364-06. The following shall apply:
a. Single contact.
b. Brass or copper base alloy gage.
c.
Plating to be the same generic materials.
measured followed by contact resistance (see 4.8.8).
14